Automatic
switching unit for reliable and continuous ambient vaporizer
operation.
The automatic
switching unit directs the cryogenic gas flow alternately
to either of the pair of ambient vaporizers, and thus enables
the off-stream vaporizer defrosting.
The switching
is time controlled with the period operator selectable within
a range of 1 to 24 hours.
The gas
passage is blocked by means of electrical solenoid valves
(normally open).
The switching
unit can be placed either on liquid or gas side of the vaporizers.
| Parameters |
| Nominal
diameter |
DN25 |
|
Nominal pressure |
PN25 |
|
Operating temperature |
-196°C to +50°C |
| Connections |
M40x2 (std.) |
|
Electrical Supply |
230
V / 50 Hz |
| Dimensions |
approx. 450 x 250 x 1000 |
|
Weight |
approx. 25 kg |
| Capacity |
up to 1500 Nm³/hr liquid
up to 300 Nm³/hr gas |
|